Replacing Commpressor air line.

User Tag List

Results 1 to 7 of 7

Thread: Replacing Commpressor air line.

  1. #1
    Join Date
    Mar 2013
    Location
    Tennant Creek, Northern Territory, Australia.
    Posts
    22,713
    Post Thanks / Like
    Real Name
    Mark
    Mentioned
    18 Post(s)
    Tagged
    0 Thread(s)

    Replacing Commpressor air line.

    The airline that goes from the tank to the tank to the pressure switch burst, its easy to disconnect the line from the tank but under the pressure switch there appears to be a shroud covering the other end, is there any way to undo it with out removing the pressure switch.

    The Compressor is a SIP Eagle 2.5hp

    Inkedunnamed (4)_LI.jpg


    COOPER 01/08/1998-31/01/2012

     
     
  2. #2
    Join Date
    Sep 2013
    Location
    South Africa
    Posts
    217
    Post Thanks / Like
    Mentioned
    0 Post(s)
    Tagged
    0 Thread(s)
    I had a similar problem with a customers compressor.
    Only way I could fix it was to remove the pressure switch.
    Awkward but do-able

     
     
  3. #3
    Join Date
    Mar 2013
    Location
    Tennant Creek, Northern Territory, Australia.
    Posts
    22,713
    Post Thanks / Like
    Real Name
    Mark
    Mentioned
    18 Post(s)
    Tagged
    0 Thread(s)
    I removed the pressure switch the line was a push in, once it was removed it was easy to get out.

    8A769DFC-D289-4A1E-9794-D3470B292ACE.jpg

    I replaced it with the one off the spare regulator and pressure switch I had that I wanted to use on the upright compressor project.

    Once I had put it back together fired it worked beautifully a couple of cycles then the freaking line burst.

    8933977C-9355-4AB9-8059-1A0DB6C77DEA.jpg

    I guess the next step is to try to relplace it with a copper line?

    COOPER 01/08/1998-31/01/2012

     
     
  4. #4
    Join Date
    Mar 2018
    Location
    middlesbrough
    Posts
    589
    Post Thanks / Like
    Real Name
    Dave
    Mentioned
    4 Post(s)
    Tagged
    0 Thread(s)
    Is there a reason it keeps bursting may be ?.

     
     
  5. #5
    Join Date
    Mar 2013
    Location
    Tennant Creek, Northern Territory, Australia.
    Posts
    22,713
    Post Thanks / Like
    Real Name
    Mark
    Mentioned
    18 Post(s)
    Tagged
    0 Thread(s)
    First time it burst I was using an air chisel 10 - 12 hrs a day with hardly a break.
    This time it is a quality chinese hose, previous one was Taiwanese.

    COOPER 01/08/1998-31/01/2012

     
     
  6. #6
    Join Date
    Sep 2013
    Location
    South Africa
    Posts
    217
    Post Thanks / Like
    Mentioned
    0 Post(s)
    Tagged
    0 Thread(s)
    Did you use one of those brass inserts that fit inside the pipe to give it a bit more strength near the fitting?

     
     
  7. #7
    Join Date
    Nov 2019
    Location
    Saskatoon, Saskatchewan, Canada
    Posts
    201
    Post Thanks / Like
    Real Name
    Peter
    Mentioned
    3 Post(s)
    Tagged
    0 Thread(s)
    If you have a place near you that makes up hydraulic lines they could make a line to fit and give you the correct fittings for the tank and regulator. It might be the rigid lines are stressed when installed and the vibrations will make them crack. The hose will not be subject to the vibrations and medium pressure hose can easily handle the pressure many times over. I have one on my compressor in a different location.

    Pete

     
     